VISCOSITY
CONTROLLER
These viscosity controller systems are controlled by sensing viscosity through the loads placed on the diaphragm pump.The evaporation of solvent in the tank causes the liquid viscosity become thickens.As the liquid viscosity hickens,the load on the pump is also increased.Then the pump cycle is getting slow. As the liquid viscosity thins,the load on the pump is also decreased.Then the pump cycle is getting fast.
Model & Parameters
Model | BML-10V |
Dimensions | 760x350x280mm |
Appearance | 304 Stainless steel |
Net weight | 19KG |
Control precision | No.3:13-30s |
Control precision | 2% |
Delivery hose | 10x6.5mmx2m |
Suction hose | 11x8mmx2 |
Circulation volume | 3.9 liters/min |
Air consumption | 40 liters/min |
Working pressure | 4 Bar |
Working voltage | 220V |
Max.volume of Sub-tank | 20L |
Model | BML-15V |
Dimensions | 760x350x280mm |
Appearance | 304 Stainless steel |
Net weight | 21KG |
Control precision | No.3:13-30s/No4:13-50s |
Control precision | 2% |
Delivery hose | 11x8mmx2.3m |
Suction hose | 14x10mmx2.3m |
Circulation volume | 8.8 liters/min |
Air consumption | 90 liters/min |
Working pressure | 4 Bar |
Working voltage | 220V |
Max.volume of Sub-tank | 40L |
Model | BML-20V |
Dimensions | 760x350x280mm |
Appearance | 304 Stainless steel |
Net weight | 25KG |
Control precision | No4:13-50s |
Control precision | 2% |
Delivery hose | 25x16mmx2.5m |
Suction hose | 23x16mmx2.5m |
Circulation volume | 19 liters/min |
Air consumption | 160 liters/min |
Working pressure | 4 Bar |
Working voltage | 220V |
Max.volume of Sub-tank | 80L |
BEFORE USEViscosity Change With Manual Adding Solvent
AFTER USEViscosity Change With Viscosity Controller Adding Solvent Automatically
Principle Sketch Map
The Viscosity Present Value returns the beginning value.
EXAMPLES OF INSTALLATION
Direct circulation
Circulation through sub ink-tank
Circulation through sub ink-tank with using circulation pump
Circulation through sub ink-tank whih circulating pump for Roll coater
Circulation through sub ink-tank for ink chamberWe are explaining how to install in case of using lnks by the following illustrations.But if you would like to use Ashesives, Coating or Varnish,you can install in the same condition as inks.
CONSTRUCTION SITE
HONOR